Electromagnetic flow metering ensures accuracy and offers reliability
For more than 40 years GEA Diessel develops and manufactures flow metering systems.
In the process industry, the electromagnetic flow meter has a special position in the flow metering technology.
The measuring principle (Faraday's law) is most suitable for this application and offers the following advantages:

The New IZMAG
- The electromagnetic flow metering technology is maintenance and wear-free because there are no parts built-in or in motion
- Density, viscosity, and temperature of the liquid do not influence the electromagnetic flow metering process
- The design is sanitized thus enabling an easy and effective cleaning, even with CIP or SIP procedures
- The smooth measuring pipe nearly causes no additional pressure loss in the product line
- The well-proven technology of the electromagnetic flow meters results in a high reliability of the measuring point
- The measuring accuracy, linearity, and reproducibility to be achieved also complies with Weights & Measures requirements
- The dynamic adaption of the measuring ranges covers a variety of flow ranges
- Compared with other flow metering technology, the electromagnetic flow meters offer an excellent price/performance ratio
With the IZM™ family GEA Diessel created a product covering all essential applications for the flow or volume metering. GEA Diessel's product range in the field of electromagnetic flow meters offers you various possibilities.
|
|
The IZMAG:
an optimum standard |
Individual system solutions with types IZM-S™ und IZM-T™ |
|
Hygiene |
made entirely of stainless steel
aseptic process connection as per DIN 11864 |
|
|
Features |
rotatable graphics display
water-protected touch keys
freely selectable process connections
maintenance-free design
vacuum-tight liner |
temperature measurement |
|
Quality Assurance |
continuous internal monitoring of functions and the measurement chain
plain text messages
digital status output
internal calibration function |
OIML certificate for use in equipment subject to weights and measures approval (MID approval procedure)
generation of a test certificate as a QM record
setting data can be archived on a PC |
|
Performance |
all liquids with a minimum conductivity >5 μS/cm
bidirectional flow measurement
flow range 5 l/h to 1,000 m³/h
3 digital outputs for volume pulses and status signal
analogue signal for flow rate
digital signal input for zero setting or measurement suppression (CIP) |
storage of metering process data
manual or automatic data transmission via GSM/GPRS
automatic shut-off calculation for high filling level accuracy |
|
User-friendliness |
operator instructions in plain text
automatic selection of measurement range
no special tools required for parameter setting |
simple remote display allowing main display to be set to zero |
Published material in this technology: