The processing of sterile and non-sterile liquids, such as blood plasma have specific purity requirements that can only be achieved with great technical skill and experience.
Preparation and pressure vessels from GEA Diessel set new performance standards and ensure that our customers 'central process components' have competitive advantages.
The surfaces of our preparation and pressure vessels are ground and polished, and as required, electro-polished. All welds are smoothed to the current GMP-/ FDA-standards and exclude even the smallest cleaning dead spaces.
GEA Diessel Preparation and Pressure Vessel profile:
|
| Volume: |
2 to 20,000 liters nominal capacity |
| Material: |
stainless steel 316L, 316Ti, 904L |
| Surface finish: |
to >= 0,2 µm |
| Surface polishing: |
mechanical and/or electro-chemical
|
| Pressure: |
pressureless and / or -1 / 10 bar (g)
|
| Temperature: |
-20/ + 200 °C |
| Cleaning options: |
CIP / SIP |
| Design: |
Single, double and triple wall design, heatable, insulated |
Examples:
-
preparation vessel for production of highly sterile products
-
buffer preparation vessel for blood plasma fractionation
-
media preparation for pharmaceutical fermentation processes
Whether for stationary or mobile use: equipment options are available, including vessel designs with simple surfaces.
Every functional element required for the process, can be integrated into the preparation and pressure vessel:
-
hand-hole for drug addition
-
magnetic coupled agitator
-
agitators with double mechanical seal
-
gassing
-
sampling valve
-
sight glass with lamp
-
temperature measuring device
-
sterile aeration filters
-
powder inlet valve
-
homogenizing
-
sterile ingredient additions
Volume and weight calculation programme
With this progamme you can easily define the dimensions of a vessel - volume, level and weight. http://www.gea-behaelter.de/index_e.html