Device compensation, directly in the running process
With solid, technically matured technology and longtime practical experience
GEA Diessel stands as a reliable partner in the field of flow metering of
liquids for most various applications.
Not only the single device but also the customers problem solving is GEA
Diessel's focus. That way, niche applications arose in the last decades, which
partly found a place in the standard products or which simply created a new
application profile.
Calibration By Means Of Reference Meter and Calibration Function Type
DI-MASTER™
GEA Diessel's electromagnetic flow meters type IZM are suitable for the
measurement of all liquids with a minimum conductivity of 5 µS/cm.
The typical measuring tolerence of the device IZM-S™ is at +/- 0.25%. In order to calibrate the flow meter
directly in the process with a master meter, an accuracy of at least +/- 0.1%
is required. A special software and calibration complies with this demand.
For 5 flow rates, this device configuration offers a compensation of the
electromagnetic flow meter IZM-S™
A> to a deviation 'zero'!
Features:
- Measuring accuracy of +/- 0,1 %
- It is not necessary to disassemble the meter to be checked, i.e. low
checking expenditure
- Measurement "in motion" during the running production
- Automatic calibration of GEA Diessel meters is possible
- Documentation by means of printer or data base on a PC
Rotary piston meters, turbine meters, electromagnetic flow meters etc.
can equally by checked. Several "master meters" on a mobile frame can cover the
whole flow range of a company.
"Control of inspection, measuring and test equipment" - an important topic
for you?
Just contact us!
For further information to the electromagnetic flow meter IZM-S™ please
refer to data sheet D12.70